JZY-4000A This high-precision full-automatic melt flow rate meter is used to measure the melt flow rate MFR/MVR value of various plastics and resins passing through a certain temperature and load in the viscous flow state. It is applicable to polycarbonate, polysulfone, fluoroplastic, nylon and other engineering plastics with high melting temperature, as well as polyethylene (PE), polystyrene (PS), polypropylene (PP), ABS resin Polyoxymethylene (POM), polycarbonate (PC) resin and other plastics with low melting temperature are widely used in plastic production, plastic products, petrochemical and other industries, as well as relevant colleges, research institutions and commodity inspection departments.
Product details
Full automatic melt flow rate meter
Model: JZY-4000A
1、 Product introduction:
This is a high-precision full-automatic melt flow rate meter, which is used to measure various plastics and resins passing through a certain temperature and load in the viscous flow state, and passing through the standard die every 10min; The MFR/MVR value of melt flow rate is applicable to engineering plastics such as polycarbonate, polysulfone, fluoroplastic and nylon with high melting temperature, as well as testing plastics with low melting temperature such as polyethylene (PE), polystyrene (PS), polypropylene (PP), ABS resin, polyoxymethylene (POM) and polycarbonate (PC) resin. It is widely used in plastic production, plastic products, petrochemical and other industries, as well as relevant universities Scientific research institutions and commodity inspection departments< br />
2、 Executive standard:
GB/T3682-2000
Thermoplastics Determination of melt flow rate and melt volume flow rate
ISO 1133:1997
Thermoplastics Determination of melt mass flow rate MFR and melt volume flow rate MVR
ASTM D1238
Standard Test Method for Melt Flow Rate of Thermoplastics by Extrusion Plastometer
3: Product advantages:
Multi segment (3-segment) temperature control mode, 3 sets of platinum resistance sensors, 3 heating jackets for independent temperature control, high-precision intelligent PID control, and adjustable temperature rise slope, i.e. temperature rise speed
The temperature resolution is 0.1 ℃, the temperature uniformity is 0.2 ℃, and the temperature fluctuation within 24 hours does not exceed 0.5 ℃,
The resolution of displacement sensor is 0.001 mm.
Temperature over temperature protection device
Manual and automatic cutting is integrated, and the cutting time (0~999) and cutting times (0~999) can be set at will
The mass method, volume method or both methods can be selected for the test, and the flow rate ratio can be calculated. Both methods start the test when the piston rod moves to a certain position.
Built in temperature stability prompt alarm, and add 240 seconds (GB3682) material preheating second countdown. After the countdown, a prompt tone will be given, and American Standard (ASTM) and other preheating time can also be set.
Built in a variety of plastic material melt index test conditions, convenient for customers to use at any time, reduce the tedious workload, and store the last test conditions and results
Built in micro printer for easy printing of test data
High precision touch screen controller, 7-inch touch screen, can store and print the latest test conditions and data. The setting of the test and print menu includes the test time (default of the system), operator, material name, test method, test conditions (temperature, weight, cutting time interval), test result data, test result, artificial judgment of OK or NG, etc,
RS232 interface or USB interface is reserved to connect with computer, which can control instrument operation and transmit and save test data to computer,
The weight can be loaded manually or the ball screw can be driven to rotate by a stepping motor to automatically control the rise or fall of the top loading weight
4、 Main technical parameters:
Temperature range: 0 ℃ - 450 ℃
Temperature fluctuation:± 0.2℃
Temperature uniformity:± 1℃
Temperature display resolution: 0.1 ℃
Time display resolution: 0.1S
Barrel diameter:Φ 2.095± 0.005mm
Discharge port length: 8.000± 0.025mm
Diameter of charging barrel:Φ 9.550± 0.025mm
Weight precision:± 0.5%
Output mode: micro automatic printout
Cutting mode: manual and automatic cutting
Test load: 8 levels in total, 8 sets of weights
Power supply voltage: AC220V± 10% & nbsp; 50HZ
5、 Melt index accessories list:& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;& nbsp;
Serial No
First Name; call
Company
quantity
remarks
one
host
platform
one
Including printer
two
Weights
set
Totally 8 grades 0.325 kg, 1.200 kg, 2.160; kg,3.800 kg,5.000 kg,10.000 kg,12.000 kg,21.600 kg
(1 # is within level 1 load)
three
Weight tray
piece
one
Within load level 1
four
piston rod
piece
one
Within load level 1
five
Die
piece
one
Tungsten carbide
six
Charging hopper
piece
one
stainless steel
seven
Charging rod
piece
one
eight
Barrel cleaning rod
piece
one
nine
Die cleaning rod
piece
one
stainless steel
ten
Gauze
volume
two
eleven
Printing paper
volume
two
twelve
other
Certificate of conformity, instruction manual, one discharge tray